Carbon fiber on-line detector for monitoring human blood serum reductive capacity. A complex technical solution

Warning

This publication doesn't include Faculty of Medicine. It includes Faculty of Science. Official publication website can be found on muni.cz.
Authors

HRBÁČ Jan NOVÁK David KNOPF Petr ŠVARC Marek VACEK Jan

Year of publication 2018
Type Article in Periodical
Magazine / Source Journal of Electroanalytical Chemistry
MU Faculty or unit

Faculty of Science

Citation
web http://dx.doi.org/10.1016/j.jelechem.2018.02.037
Doi http://dx.doi.org/10.1016/j.jelechem.2018.02.037
Keywords Carbon fiber Microelectrode On-line sensing Amperometry Clinical sample Trolox
Description The construction of a cylindrical carbon fiber on-line detector is presented, featuring a novel way of sealing the carbon fiber microelectrode, the design of an interchangeable carbon fiber microelectrode-based flow cell and its interface with data acquisition electronics. The two-electrode setup was used, where the regeneration of the carbon fiber working electrode surface between analyses was performed using an electrochemical procedure, typically -1/+1V potential cycling. The detector was incorporated into the flow injection analysis manifold and the applicability of the developed sensing platform tested for monitoring a hexacyanoferrate (II/III) redox probe and the oxidizable compounds trolox (6-hydroxy-2,5,7,8-tetramethylchroman-2-carboxylic acid), uric acid, and l-ascorbic acid, with dehydroascorbic acid as a negative control. Finally, the optimized procedure was utilized for the analysis of human blood serum reductive (antioxidant) capacity based on amperometric sensing and flow injection analysis at a flow rate of 10ul/min. Amperometric responses for blood serum samples were evaluated for standard deviation, whose average value was estimated to be ±0.3nA (n=20). The electrolytic efficiency of the detector was on the order of % units, e.g. 2% for trolox. The flow cell geometry and application of carbon fiber electrodes resulted in the absence of dead volumes and passivation phenomena, in contrast to conventional high-surface-area electrochemical cells. We suppose that the complex technical solution presented here could find a broad range of applications in the on-line monitoring of other reducing low-molecular bioactives and of the redox properties of various body fluids or clinical samples.

You are running an old browser version. We recommend updating your browser to its latest version.

More info